Checking Intake Air System For Leaks (Unmetered or False Air)
Intake Air System, Checking For Leaks
Required special tools and test equipment
- VAG1551 or VAG1552 Scan Tool (ST) with VAG1551/3 adapter cable
- Engine leak detector spray G 001 800 A1
NOTE:
- If there are leaks, intake manifold vacuum will draw in the leak detector spray with outside air. The spray reduces the ability of the fuel/air mixture to ignite, which causes a drop in engine speed and a significant increase in CO-content.
- Observe the safety precautions listed on the container
Checking
- Connect VAG1551 or VAG1552 scan tool and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (with engine running at idle). Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks/Connecting VAG 1551/1552 Scan Tool" Testing and Inspection
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08, and press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block HELP
Input display group number XXX
- Press buttons -0-, -0- and -1- to input display group number 1 (001), and press -Q- button to confirm input.
- Systematically spray parts of intake air system with engine leak detector spray.
If engine speed drops, or the values displayed for oxygen sensor control change:
- Check for leaks in area of intake air system most recently sprayed, and eliminate leaks.
Indicated on display (1-4 = display fields)
Read Measuring Value Block 1 ->
1 2 3 4
- Monitor oxygen sensor control in display fields 3 and 4.