Programming Control Module (ECM) -J248-, (Function 07)




Code Control Module (Function 07)

Equipment version with no side curtain protection system


This function can be used to code interior monitor as follows:
- Vehicle model: Audi A6
- Anti-theft alarm priming mode: static
- Body version: Saloon/Avant


NOTE:
- The coding sets the universal ultrasonic sensor control module -J347 specifically to the requirements of the respective vehicle model and the corresponding anti-theft alarm.
- The coding table only lists the possible combinations applying to the Audi A6.


Implementing function "07 - Code Control Module"

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press keys 0 and 7.

Indicated on display:


Rapid data transfer Q
07 - Code Control Module



- Confirm entry with Q key.

Indicated on display:


Code Control Module
Enter code number XXXXX (0-32000)



- Enter code number.

Code: 00001

00 Fillers, no significance
0 Audi A6
0 Static priming mode
1 Sedan
2 Avant

- Indicated on display:


Code Control Module Q
Enter code number 00001 (0-32000)



- Confirm entry with Q key.

Indicated on display:


4B0951173 Interior monitor D03 ->
Code 00002 WSC 06812



- Conclude coding by pressing -> key.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press keys 0 and 6 to terminate function.

Indicated on display:


Rapid data transfer Q
06 - End Output



- Confirm entry with Q key.

Equipment version with side curtain protection system

This function can be used to code interior monitor as follows:
- Vehicle model: Audi A6
- Body version: Sedan/Avant


NOTE:
- The coding sets the universal ultrasonic sensor control module -J347 specifically to the requirements of the respective vehicle model and the corresponding anti-theft alarm.
- The coding table only lists the possible combinations applying to the Audi A6.


Implementing function "07 - Code Control Module"

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press keys 0 and 7.

Indicated on display:


Rapid data transfer Q
07 - Code Control Module



- Confirm entry with Q key.

Indicated on display:


Code Control Module
Enter code number XXXXX (0-32000)



- Enter code number.

Code: 00101

00 Fillers, no significance
1 Audi A6
0 Filler, no significance
1 Sedan
2 Avant

- Indicated on display:


Code Control Module Q
Enter code number 00001 (0-32000)



- Confirm entry with Q key.

Indicated on display:


4B0951173A Interior monitor D03 ->
Code 00102 WSC 08812



- Conclude coding by pressing -> key.

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press keys 0 and 6 to terminate function.

Indicated on display:


Rapid data transfer Q
06 - End Output