Operation CHARM: Car repair manuals for everyone.

Connecting and Selecting Functions


VAS5051 tester or VAG1551 scan tool, connecting and selecting functions
Test requirements:
^ Battery voltage at least 11 V
^ Ground (GND) connections at engine and transmission OK
^ Engine off
^ Automatic in position "P" or "N"

Procedure





^ Connect VAS5051 tester with VAS5051/1 diagnostic wire with the ignition switched off. Alternately, VAG1551 Scan Tool (ST) can also be attached using VAG1551/3A adapter.

Note: The following description only explains implementation of On Board Diagnostic using VAG1551 Scan tool. When using the VAS5051 tester, observe instructions in the tester's user manual.





Indicated on display:
1) Operating modes 1 and 2 are displayed alternately

Note: If nothing appears in display:

Operating instructions for Scan Toot (ST)
^ Switch ignition on.
^ Switch off level control system manually (pressing button twice > 5 seconds on manual control head).
^ Press -Print- button to turn on Scan Tool (ST) printer. Indicator lamp in button must light up.
^ Press button 1 to select "Rapid data transfer" operating mode 1.





When indicated on display:

Note: The address word 00 initiates the automatic test sequence, i.e. it results in a DTC check on all OBD capable systems in the vehicle via rapid data transfer.

^ Press "34" for address word "Level control system".





Indicated on display:
^ Press -Q- button to confirm input





Indicated on display:





^ Indicated on display after approximately 5 seconds:
^ Press button.





Indicated on display:

Note: Pressing the -HELP- button will print out an overview of all of the possible functions.

^ Press button -1- twice for the "Login procedure" and press -Q- button to confirm input.





Indicated on display:
^ Press -Q- button to confirm input





Indicated on display:
^ Press button 0, 8, 3, 6 and 7.





Indicated on display:
^ Press -Q- button to confirm input





When indicated on display:
^ Press buttons -0- and -4-





When indicated on display:
^ Press -Q- button to confirm input





When indicated on display:
^ Input display group number.
^ Press buttons -0-, -2- and -6-.
^ Press -Q- button to confirm input





When indicated on display:
^ Press button to continue





When indicated on display:

Note:
^ Press button to return to GE 26





Indicated on display after expiration of 65 seconds:

Note: However, the filling procedure can only be aborted prematurely by exiting the display group number.

^ Press button to continue





When indicated on display:
^ Press button to continue





When indicated on display:

Note:
^ Press button to return to GE 28





Indicated on display after expiration of 65 seconds:

Note: However, the filling procedure can only be aborted prematurely by exiting the display group number.

^ Press button to continue





When indicated on display:
^ Press button to continue





When indicated on display:

Note:
^ Press button to return to GE 30





Indicated on display after expiration of 65 seconds:

Note: However, the filling procedure can only be aborted prematurely by exiting the display group number.

^ Disconnect diagnostic cable from Data Link Connector (DLC)
Other filling procedures can follow in the above mentioned scheme. The order (filling air springs - front axle, air springs - rear axle, pressure reservoir ) can be specified as desired.
Note that upon exiting the filling mode, the regulation still remains manually switched off, as long as it is not switched on or a speed of v > 15 km/h is recognized.