Adaptation (Function 10)
Adaptation (Function 10)
The adaptation function makes it possible to implement and store the following modification:
- Setting of ultrasonic sensors can be adjusted such that they react less sensitively.
- Starting interior monitoring system On Board Diagnostic (OBD). On Board Diagnostic (OBD), Initiating
Indicated on display:
Rapid data transfer HELP
Select function XX
- Enter "10" to select the function "Adaptation" and confirm entry with Q key.
Indicated on display:
Adaptation Q
Feed in channel number XX
- Enter "01" to select "adaptation channel 01" and confirm entry with Q key.
Indicated on display: The sensor sensitivity level is displayed: e.g. 100 %
Channel 1 Adaptation 100 ->
Sensitivity in % <-1 3->
NOTE: The maximum ultrasonic sensor setting made at the factory is 100% and can be reduced to 50 %.
- Press -> key.
Indicated on display:
Channel 1 Adaptation 100 Q
Enter adaptation value XXXXX
- Enter desired 5-digit adaptation value e.g. 75 % = 00075
Indicated on display:
Channel 1 Adaptation 100 Q
Enter adaptation value 00075
- Confirm entry with Q key.
Indicated on display:
Channel 1 Adaptation 75 Q
Sensitivity in % <-1 3->
- Confirm entry with Q key.
Indicated on display:
Channel 1 Adaptation 75 Q
Store changed value?
- Confirm entry with Q key.
Indicated on display:
Channel 1 Adaptation 75 ->
Changed value is stored
- Terminate adaptation of sensitivity in "Adaptation channel 01" by pressing key.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX