Operation CHARM: Car repair manuals for everyone.

Programming Control Module (ECM) -J248-, (Function 07)




Code Control Module (function 07) (vehicles without side curtain airbag)

The coding sets the universal control module for ultrasonic sensors -J347 according to the requirements of the particular model version and anti-theft alarm system
- Starting interior monitoring system On Board Diagnostic (OBD). On Board Diagnostic (OBD), Initiating

Indicated on display:


Rapid data transfer HELP
Select function XX



- Enter "07" for the function "Code Control Module" and confirm entry with Q key.

Indicated on display:


Code Control Module Q
Enter code number XXXXX (0-32000)



- Enter 5-digit control module code in with table.







Indicated on display:


Code Control Module Q
Enter code number 00101 (0-32000)



- Confirm entry with Q key.

The display on the scan tool VAG 1551 will show the control module identification code (example).


4D0951173B Interior monitoring sys. D02 ->
Coding 00101 WSC 12345


- Press -> key.

Indicated on display (function selection):


Rapid data transfer HELP
Select function XX



Code Control Module (function 07) (vehicles with side curtain airbag)

The universal control module for ultra-sound sensors -J347- is set for the special requirements of the respective vehicle type and the respective ATWS.
- Initiate On Board Diagnostic (OBD) of interior monitoring. On Board Diagnostic (OBD), Initiating

When indicated on display:


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -7- to select "Code control module" and press -Q- button to confirm input.

When indicated on display:


Code control module Q
Enter code numbers XXXXX (0-32000)



- Enter valid 5-digit control module coding according to coding table.







When indicated on display:


Code control module Q
Enter code number 00001 (0-32000)



- Confirm input using the -Q- button.

Control module identification with the entered coding is indicated on display of V.A.G 1551 Scan Tool (example).


4D0951 177B Interior monitoring D02->
Coding 00001 WSC 12345



- Press -> button.

Indicated on display (function selection):


Rapid data transfer HELP
Select function XX