Reading
Measuring Value Block, Reading (function 08)
- Connect VAG 1551, insert "Transmission Electronics" address word 02 and advance through program sequence until "Select function XX" is indicated in display Connecting VAG 1551 Scan Tool
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08-Read measuring value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XXX
- Input display group number. Display group numbers.
- Press -Q- button to confirm input
Read measuring value Block 1 ->
1 2 3 4
4 display fields always appear in the measuring value block (in physical values where necessary). For specifications for values in individual display fields. Measuring Value Blocks (Function 08)