Read Measuring Value Block (Function 08)
- There are 10 measuring value blocks, each with values shown in 4 display fields.- With VAG1551 scan tool printer switched on, display is automatically printed out.
- Before reading measuring value block, check Diagnostic Trouble Code memory.
- Eliminate/repair all malfunctions as necessary, then erase DTC memory. Keep engine running.
- Operate VAG1551 scan tool, stepping through program sequence until display shows "AC/Heating Electronics" address word 08.
Indicated on display:
Rapid data transfer HELP
Select function XX
Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
NOTE: Press "HELP" button to print out list of available functions.
Indicated on display:
Rapid data transfer Q
08 - Read Measuring Value Block
Press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block HELP
Input display group number XXX
Input display group number (e.g. -0-, -0- and -1- for display group 1), then press -0- button to confirm input.
Indicated on display:
Read Measuring Value Block X
1 2 3 4
NOTE:
- For description of the 4 display fields in individual display groups, refer to tables starting on page 01-39.
- Display fields marked with an asterisk (*) indicate values when On Board Diagnostic (OBD) was initiated.
- All display fields NOT marked with an asterisk (*) indicate current values.
To select another display group press -C- button.
Indicated on display:
Read Measuring Value Block HELP
Input display group number XXX
- Input new display group number.
- Press -Q- button to confirm input.
Testing Electrical Inputs:
- Connect VAG1598 test box to A/C control head connectors using VAG1598/11 and VAG1598/12 adapter cables.
- For test box socket identification when using VAG1598/11 adapter Cable, VAG 1598 Test Box, Connecting
Description Of Display Groups and Display Fields:
Display Group: 001:
Display Group: 002:
Display Group: 003:
Display Group: 004:
Display Group: 005 & 006:
Display Group: 007:
Display Group: 008:
Display Group: 009:
Display Group: 010, Part 1:
Display Group: 010, Part 2:
1) Value when On Board Diagnostic program was first initiated
Display Group 1(001), Display Field 1 - A/C Compressor Switch-Off Conditions:
Display 0, 1 & 2:
Display 3, 4, 5 & 6:
Display 7, 8, 9 & 10:
Display 11, 12, 13 & 14:
1) Ignore display "5" or "6" if it appears in addition to these displays.