Programming and Relearning
Code Control Module (Scan Tool Function 07)
NOTE:
- Control modules are supplied uncoded.
- An uncoded control module will cause the airbag Malfunction Indicator Lamp (MIL) -K75- to light up continuously.
- The coding procedure is carried out using the VAG1551 Scan Tool (ST).
If no coding appears on the VAG1551 Scan Tool (ST), or if a new control module has been installed, carry out the coding procedure as follows:
Carrying out "Code Control Module" function 07
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -7- to select "Code Control Module" function 07.
Indicated on display
Rapid data transfer Q
07 - Code Control Module
- Press -Q- button to confirm input.
Indicated on display
Code Control Module
Enter code number XXXXX (0-32000)
- Enter coding for airbag control module using keypad:
Vehicles From 1999: from VIN 8D XA 200 001 on
Coding table for airbag control module
Indicated on display (e.g. 00104)
Code Control Module Q
Enter code number 00104 (0-32000)
- Press -Q- button to confirm input.
Indicated on display (control module identification will appear on display together with coding that has been entered, e.g. 00104).
8D0959655K Airbag Front+Side D00 ->
Coding 00104 WSC 06812
- Press -> button.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -6- to select "End Output" function 06.
Indicated on display
Rapid data transfer Q
06-End Output
- Press -Q- button to confirm input.
Indicated on display
Rapid data transfer HELP
Input address word XX
All vehicles:
Indicated on display (e.g. 00102):
Code Control Module Q
Enter code number 00102 (0-32000)
- Press -Q- button to confirm input.
Display indicates control module identification with coding input (e.g. 00102).
8D0959655C Airbag 7 AUDI D00 ->
Coding 00102 WSC 06812
NOTE:
- Coding 00102, 00104 and 00106 can only be used for control module number "8D0959655D" or "8D0959655M."
- Explanation of display.
- Push -> button.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -6- to select "End Output" function 06.
This ends the function.
Indicated on display
Rapid data transfer Q
06 - End Output
- Press -Q- button to confirm input.
Indicated on display
Rapid data transfer Help
Insert address word XX