Operation CHARM: Car repair manuals for everyone.

Adapting SRI For Inspection Service Interval-1 (IN1) (Distance In km)



Adapting SRI For Inspection Service Interval-1 (IN1) (Distance In km)
This function is used to enter the distance remaining (distance in km) until the next maintenance service is due (see service schedule Maintenance Service").

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10 and press -Q- button to confirm input.

Indicated on display


Adaptation Q
Insert channel number XX



- Press buttons -0- and -6- to insert channel 06.
- Press -Q- button to confirm input.

Indicated on display


Channel 6 Adaptation 5
<-1 3->



The display shows the number of kilometers remaining until the next maintenance service is due (the "5" indicates 5000 km remaining).


NOTES:
- Values can only be entered in increments of 1000 km. Therefore, the distance indicated is in units of 1000.
- In countries where speedometers are calibrated in miles, adjustments must still be made in kilometers. Therefore convert miles to kilometers (miles x 1.609 = kilometers) to get the required adaptation value.
- If the instrument cluster must be replaced, observe notes. Input Values For Instrument Cluster Replacement
- When using the scan tool keypad, only the direct input method can be used.
- If an incorrect value is input, the "adaptation" function 10 will be cancelled and must be initiated again.


- Press -> button.

Indicated on display


Channel 6 Adaptation 11
Input adaptation value XXXXX



- Input desired interval value using keypad on VAG1551, fill in leading digits with zeroes "0."

Example:
Specification: 30000 km
Input value: 00030

Indicated on display


Channel 6 Adaptation 11 Q
Input adaptation value 00030



- Press -Q- button to confirm input.

Indicated on display


Channel 6 Adaptation 30 Q
<-1 3->



- Press -Q- button to confirm input.

Indicated on display


Channel 6 Adaptation 30 Q
Store changed value?



- Press -Q- button to confirm input.

Indicated on display


Channel 6 Adaptation 30 ->
Changed value is stored



- Press -> button to end SRI adaptation.

Indicated on display


Rapid data transfer HELP