Reading
Initiating "Read Measuring Value Block"
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8-. This selects "Read measuring value block", function 08.
Indicated on display
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block HELP
Input display group number XXX
- Input display group number 066 (engine must be running at idle)
- Press -Q- button to confirm input.
The selected measuring value block is now displayed in standard form.