Torque Converter Installing
^ Push torque converter hub through seal as far as first stop on transmission shaft.
^ Press and rotate torque converter by hand until recess of torque converter hub engages in driver of pump gear and torque converter is felt to slip in to proper position.
Installation dimension
If the torque converter is correctly inserted, the distance between the faces of the threaded hole at the torque converter and the contact surface of the torque converter bell housing is approximately 23 mm (0.91 inch).
If the torque converter is not fully inserted, this distance is approximately 11 mm (0.43 inch).
CAUTION! If the torque converter is not inserted correctly, the driver of the ATF pump will be damaged when the transmission is attached to the engine.