Operation CHARM: Car repair manuals for everyone.

Basic Setting (Function 04)




Basic Setting (Function 04)

With ignition on and engine at standstill, the following operations can be performed using "function 04", basic setting:
- Adapt throttle valve control module to Engine Control Module (ECM).
- Vehicles with automatic transmission: Adaptation of kick down function of accelerator pedal position sensor to ECM.

With engine running, the following operations can be performed using basic setting:
- Adaptation of oxygen sensor control

Test requirements for operations with engine running:
- No DTCs in DTC memory.
- Coolant Temperature at least 80 °C.
- Electrical consumers switched off (radiator fan must NOT run during test).
- A/C switched off.
- Vehicles with automatic transmission Selector lever in P or N.

Test sequence
- Connect VAS5051 tester or VAG1551 scan tool and select control module for engine electronics using "address word" 01. Ignition must remain switched on. or, depending on desired operation: [1][2]Scan Tool Connecting and Initial Checks

- Start engine.

When indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- button to confirm input.

When indicated on display


Basic Setting Q
Enter display group number XXX



- Input desired display group number.

Example:
- Press buttons -0-, -0- and -0- to select "display group number 000" and press -Q- button to confirm input.


NOTE: After selecting display group number, the EVAP valve is closed and A/C compressor switched off


Indicated on display


System in basic setting 0 Q
1 2 3 4 5 6 7 8 9 10



NOTE:
- For display group number 000, measured values are displayed as a decimal.
- Display can be printed out when printer is switched on.
- To switch to a different display group, proceed as follows:







- If specified values are obtained in all display fields, press -> button.

Indicated on display (function selection)


Rapid data transfer HELP
Select function XX