Reading
Read Measuring Value Block (Scan Tool Function 08)
NOTE: The current airbag system condition can be determined by using the "Read Measuring Value Block" function 08.
Carrying out "Read Measuring Value Block" function 08
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08-Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block
Input display group number XXX
- Press buttons -0-, -0- and -1- to input display group number 1(001).
- Press -Q- button to confirm input.
The selected Measuring Value Block is now shown in standard format.