System Description/Adaption Table/Initiating Adaption Function 10
Function 10 is used to initiate and store the following changes:
- Adaptation of fuel gauge display
- Correction of the fuel consumption display
- Coding of language versions for Auto Check system
- Adaptation of the Service Reminder Indicator (SRI)
- Setting the odometer after instrument cluster replacement.
Individual functions are called up by entering the appropriate adaptation channel number (see adaptation table below).
Adaptation Table
Adaptation channel Adaptation function
01 Adaptation of fuel guage display
02 Resetting SRI after service
03 Adaptation of fuel consumption display
04 Language versions of the multi-function display
05 SRI - service interval for oil change (distance in km)
06 SRI - service interval 1 (IN1) distance in km
07 SRI - service interval 1 (IN1) time in days
08 SRI - service interval 2 (IN2) lime in days
09 Adapting odometer reading
M.y. 1998 >
Adaptation Channel Adaptation Function
10 SRI Remaining distance until next oil change service interval after replacing instrument cluster.
11 SRI Remaining distance until next service interval after replacing instrument cluster.
12 SRI Remaining time until next service interval after replacing instrument cluster.
30 Adaptation of fuel gauge sender.
Initiating "Adaptation" Function 10
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
Indicated on display
Read Measuring Value Block Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation Q
Insert channel number XX
- Insert desired adaptation channel.
- Press -Q- button to confirm input.
NOTE: After changing an adaptation value or after an adaptation in a specific channel has been completed, "Adaptation" function 10 must be selected again in order to select another adaptation channel.