Ignition System: Testing and Inspection
Misfire Recognition, Checking
Special tools and equipment
- VAS5051 with VAG5051/1
or
- VAG1551 with VAG1551/3A
Test sequence
- Connect VAS5051 tester or VAG1551 scan tool and select control module for engine electronics using "address word" 01. Engine must run at idle. Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks" Testing and Inspection
When indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" and press -Q- button to confirm input.
When indicated on display
Read measuring value block Q
Enter display group number XXX
- Press buttons -0-, -1- and -4- to select "display group number 014" and press -Q- button to confirm input.
When indicated on display
Read Measuring Value Block 14 ->
1 2 3 4
- Check misfire recognition.
Display Group 014:
If specified value is obtained:
- Press -> button.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
If specified value is not obtained:
- Press -C- button.
Check misfire recognition of the individual cylinders.
When indicated on display
Read measuring value block Q
Enter display group number XXX
- Press buttons -0-, -1- and -5- to select "display group number 015" and press -Q- button to confirm input.
When indicated on display
Read Measuring Value Block 15 ->
1 2 3 4
- Check misfire recognition in display fields 1 to 4.
Display Group 015:
- Press -C- button.
When indicated on display
Read measuring value block Q
Enter display group number XXX
- Press buttons -0-, -1- and -6- to select "display group number 016" and press -Q- button to confirm input.
When indicated on display
Read Measuring Value Block 16 ->
1 2 3 4
- Check misfire recognition in display fields 1 and 4:
Display Group 016:
Evaluation display group 014, display field 3 and display group 015 and 016, display fields 1, 2 and 3.