Refrigerant Lines From Denso Compressor
Refrigerant Lines From Denso Compressor (with A/C Clutch -N25- ), Removing And Installing
- Discharge refrigerant circuit.
- Remove bolts -A- and -B- (tightening torque 25 Nm).
- O-Ring-seals-C- (23.8 mm x 2.4 mm) and -D- (11.1 mm x 1.8 mm) replacing.
NOTE:
- There may be different methods for installing the refrigerant lines to the connecting flange.
- Do not use the O-rings from the shipping caps that are installed on the connections when installing lines.
- Seal off all open refrigerant lines and connections on the compressor.