Adaptation For Comfort System Databus
Adaptation
Individual functions are called up by entering the appropriate adaptation channel numbers (listed in the adaptation table).
NOTE:
- Using measuring value blocks 10,11, 12 and 15, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42-44 (see measuring value blocks 13 and 14) do not need to be transferred when replacing instrument cluster, because they are adjusted by the factory for each new instrument cluster
Adaptation table:
Initiating "Adaptation" function 10
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
- Press -Q- button to confirm input.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Insert channel number XX
- Enter desired adaptation channel (adaptation table).
- Press -Q- button to confirm input.
NOTE: After changing an adaptation value or ending an adaptation channel, "Adaptation" function 10 must be performed again before selecting another adaptation channel.
Adaptation for comfort system databus
NOTE:
- The adaptation values of the table are input.
- Observe notes when replacing instrument cluster.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Insert channel number XX
- Press buttons 6- and 1-.
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 0 ->
<-1 3->
- Press -> button.
Indicated on display:
Channel 61 Adaptation 0
Input adaptation value XXXXX
- Input desired value via scan tool keypad using table, fill initial positions with "0."
e.g. desired input value: 768 with tire pressure control
Keypad input: 00768
Indicated on display:
Channel 61 Adaptation 0 Q
Input adaptation value 00768
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 Q
<-1 3->
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 Q
Stored changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 ->
Changed value is stored
- Conclude adaptation of comfort system databus by pressing the -> button.
Table
Equipment Adaptation value
Instrument cluster 256
Tire pressure 512
Parking assistance 16384
Auxiliary heater 32768
Installed control modules that participate in the comfort system databus for the Audi A8 (measuring value block, see "Measuring value block 130") are added.
NOTE: The instrument cluster, which is CAN capable, is not indicated in the measuring value block, but must be added anyway.
Example: Tire pressure control
- Instrument cluster + tire pressure 256 + 512 = 768