NOTE: Panel gaps can be checked using special tool 3371.
Fig. 1 Panel gaps
Dimension A = 4 mm + 1 mm
Dimension B = 4 mm + 1 mm
Dimension C = 3.5 to 4.5 mm
Dimension D = 5 mm ± 1.5 mm
Dimension E = 3.5 mm + 1 mm
Fig. 2 Adjusting door at striker plate
- Loosen bolts - 2 -.
- Move striker plate - 1 - until door shell is flush with contour of body.
- Tighten bolts.
Tightening torque: 20 Nm