Misfire Recognition, Checking
Special tools and equipment
- VAS5051 with VAG 5051/1
or
- VAG 1551 with VAG 1551/3A
Test sequence
- Connect VAS 5051 tester or V.A.G 1551 scan tool and select "Address word" 01 for control module for engine electronics.
- The engine must run at idle for this test.
When indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons "08" for the function "read Measuring Value Block" and press Q button to confirm input.
When indicated on display
Read Measuring Value Block Q
Input display group number XXX
- Press buttons "014" on for "Display group number 14" and confirm by pressing the Q button.
When indicated on display
Read Measuring Value Block ->
1 2 3 4
- Check the misfire recognition
Display Group 14:
If the specified value is met:
- Press -> button.
Indicated on display (function description):
Rapid data transfer HELP
Select function XX
Evaluation Display Group 003