Oxygen Sensor Aging
Oxygen Sensor (O2S) Aging (HO2S Before TWC), Checking
Special tools and equipment
- VAG1788/10 RPM adjuster
- VAS5051 with VAG5051/1
or
- VAG1551 with VAG1551/3B
Test requirement:
- Coolant temperature at least 80 degree C display group 4, display field 3.
Test sequence
- Connect VAS5051 tester or VAG1551 scan tool and select the control module for engine electronics using "address word" 01. Connecting VAS 5051/VAG1551 Scan Tool
Engine must run at idle for this.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- button to confirm input.
Indicated on display:
System in Basic Setting Q
Input display group number XXX
- Press buttons -0-, -3- and -4- to select "display group number 034" and press -Q- button to confirm input.
Indicated on display:
System in Basic Setting 34 ->
1 2 3 4
- Use VAG1788/10 RPM adjuster to adjust engine speed to between 1800 and 2200 RPM.
- Continue test as soon as display 4 indicates "Test ON".
NOTE: This process can take a few minutes.
Display Group 034:
Continued
If specified value in display field 3 and 4 is not obtained:
- Road test vehicle in order to free oxygen sensor of possible residue and repeat test.
If specified value in display field 3 and 4 is not obtained, even after road test:
- Replace Heated Oxygen Sensor (HO2S) -G39-.