Ultrasonic Interior Monitoring On Board Diagnostic, Initiating
Requirements
- Fuse OK according to wiring diagram
- VAG1551 Scan Tool (ST) connected. VAG1551 Scan Tool (ST), Connecting
- Anti-theft system not armed
NOTES:
- If the display remains blank, check VAG1551 voltage supply according to wiring diagram.
- The scan tool HELP button can provide additional operating instructions.
- The -> button is used to advance through the program sequence.
- If an incorrect entry is made, press the -C- button to escape.
- Switch ignition on.
- Switch printer on by pressing PRINT button (indicator lamp in button lights up).
- Press button -1 - to select "Rapid data transfer" operating mode 1.
Indicated on display
Rapid data transfer HELP
Insert address word XX
Address word for interior monitoring: 45
- Press buttons -4- and -5- to insert "lot. Monitoring" address word 45.
Indicated on display
Rapid data transfer Q
45 - Int. Monitoring
- Press -Q- button to confirm input.
Indicated on display after about 5 seconds
4B0951173 Int. Monitoring D00 ->
Coding 00101 WSC 06812
- Press -> button.
NOTE: A list of available functions is printed out when the HELP button is pressed.
On Board Diagnostic (OBD) Functions
The following functions are possible.
01 - Check Control Module Versions. Testing and Inspection
02 - Check DTC Memory. Check DTC Memory (Function 02)
03 - Output Diagnostic Test Mode. Output Diagnostic Test Mode (Function 03)
05 - Erase DTC Memory. Erase DTC Memory (Function 05)
06 - End Output. End Output (Function 06)
07 - Code Control Module. Testing and Inspection
08 - Read Measuring Value Block. Read Measuring Valve Block (Function 08)
10 - Adaptation. Programming and Relearning