Fuel Level Sensor, Adaptation After Replacement




Adaptation (Scan Tool Function 10)

Function 10 is used to initiate and store the following changes:
- Adaptation of fuel gauge display
- Correction of the fuel consumption display
- Coding of language versions for Auto Check system
- Adaptation of the Service Reminder Indicator (SRI)
- Setting the odometer after instrument cluster replacement.

Individual functions are called up by entering the appropriate adaptation channel number (See adaptation table).

Adaptation table

Adaptation channel Adaptation function

01 Adaptation of fuel gauge display
02 Resetting SRI after service
03 Adaptation of fuel consumption display
04 Language versions of the multi-function display
05 SRI - service interval for oil change (distance in km)
06 SRI - service interval 1 (IN1) distance in km
07 SRI - service interval 1 (IN1) time in days
08 SRI - service interval 2 (IN2) time in days
09 Adapting odometer reading
10 SRI Remaining distance until next oil change service interval after replacing instrument cluster
11 SRI Remaining distance until next service interval after replacing instrument cluster
12 SRI Remaining time until next service interval after replacing instrument cluster
30 Adaptation of fuel gauge

Initiating "Adaptation" function 10

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select "Adaptation" function 10.


Read Measuring Value Block Q
10 - Adaptation



Indicated on display

- Press -Q- button to confirm input.

Indicated on display


Adaptation Q
Insert channel number XX



- Insert desired adaptation channel (See Adaptation table).
- Press -Q- button to confirm input.


NOTE: After changing an adaptation value or after an adaptation in a specific channel has been completed, Adaptation" function 10 must be selected again in order to select another adaptation channel.


Adaptation of fuel gauge sender
This function is used to adjust the resistance range for the fuel gauge sender in order to compensate for any misalignment of the fuel gauge.

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -1- and -0- to select function 10 and press -Q- button to confirm input.

Indicated on display


Adaptation
Insert channel number XX



- Press buttons -3- and -0- to insert channel 30.
- Press -Q- button to confirm input.

Indicated on display


Channel 30 Adaptation 128 ->
< -1 3- >



The display shows the adaptation value, for example 128.


NOTE:
- 128 is the adaptation value for the standard resistance range for the fuel gauge sender as set by the factory.
- The resistance value for the fuel sender resistance range can be adjusted by ±8 ohms to give an adaptation value between 120 and 136.


- Press -> button.

Indicated on display


Channel 30 Adaptation 128
Input adaptation value XXXXX



- Input adaptation value using keypad on VAG1551, fill in leading digits with zeroes "0"

Indicated on display


Channel 30 Adaptation 128 Q
Input adaptation value 00132



- Press -Q- button to confirm input.

- Indicated on display


Channel 30 adaptation 132 Q
< -1 3- >



- Press -Q- button to confirm input.

- Indicated on display


Channel 30 adaptation 132 Q
Store changed value?



- Press -Q- button to confirm input.

- Indicated on display


Channel 30 adaptation 132 ->
Changed value is stored



- Press -> button to end SRI adaptation.