Channel 41 (Time Since Service)
ALLDATA Editor Note: By resetting the SRI on Adaptation Channel 02, Channels 40 and 41 are automatically set to "0", meaning the following procedure would only be required if a different value is needed.
Adaptation (function 10)
individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table). [1][2]Service and Repair
Initiating "Adaptation" function 10
- Initiate output Diagnostic Test Mode of instrument cluster. [1][2]Adaptation Function Initiation
Adaptation Channel 41 - Time Since Service
This function is used to input the time in days since the last service.
Display on VAS5051
- Select function "4" in button field -2- For Adaptation channel 41" and press Q button to confirm input.
Display on VAS5051
1 - Channel 41 read and test
2 - Actual value in spec. in 1 day increments.
3 - Keypad - only direct input via the keypad is possible
4 - The sliding bar is positioned on the current adaptation value, e.g. 110
Time in days since last service is displayed (here For example 110 represents 110 days)
Note:
- Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
- Change adaptation value via direct input using keypad, not with the sliding bar.
- Enter 5-digit adaptation value. Insert zeros in front.
Example:
Desired input value: For example 200 days
Keypad input: 00200
Note: The "Save" button does not appear if an incorrect value was entered!
Display on VAS5051 after performed adaptation:
1 - Channel 41 Value 200 stored
- End function "10 - Adaptation" by pressing <- button.
NOTE: After changing an adaptation value or ending an adaptation channel, "10 - Adaptation" function must be selected again before selecting another adaptation channel!