Heating and Air Conditioning: Specifications
A/C Refrigerant System With Expansion Valve And Receiver Drier
Pressures and temperatures in the A/C system vary depending on engine speed (RPM), coolant fan speed, engine coolant temperature, A/C clutch engagement, outside temperature and humidity, cooling demand etc.
Pressure and temperature specifications are to be used as a reference only, and are based on the following operating conditions:
- Engine speed 1500 - 2000 RPM
- Outside temperature of 20 °C (68 °F)
To check system pressures, pressure testing equipment must be connected to the service valves.
NOTE:
- Small -arrows- indicate direction of refrigerant flow.
- At 20 °C (68 °F) with engine not running, refrigerant system pressure equalizes to approx. 4.7 bar (68.2 psi)
- Refrigerant system pressures are regulated and maintained within certain tolerances by the variable displacement compressor independent of engine speed (RPM).
ND = low pressure side
HD = high pressure side
Pressure And Temperature Specifications
Refer to above for placement of components in refrigerant circuit.