Control Module Versions, Checking (Function 01)
Check Control Module Version
- Press buttons -0- and -1-.
Indicated on display
Rapid data transfer Q
01 check control module version
- Confirm input with -Q- button.
Indicated on display
8N8962267 Central Locking DWA D01 ->
Coding 15884 WSC 06812
Meaning of displays:
- 8N8962267A: number of Central Locking Control Module
- Central Locking: component designation and version
- Central Locking DWA (central locking + alarm): component designation and version
- D01: software version
- Coding 15884: coding
- WSC 06812: workshop code
The -> button can be used to return to the basic function mode. Indicated on display
Indicated on display
Rapid data transfer HELP
Select function XX