Fuel Consumption Display, Adapting
Fuel Consumption Display, Adapting
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- and confirm input with Q button.
Indicated on display:
Adaptation
Enter channel number XX
- Press buttons -0- and -3- to access "channel 03".
- Press -Q- button to confirm input
NOTE:
- Adaptation is only possible on vehicles with on-board computer.
- The value entered must be between 85% and 115%.
- The value must be entered in steps of 5%.
- If the value "100" was changed due to a customer complaint, the changed value must be entered into a new instrument cluster.
Indicated on display:
Channel 3 Adaptation 100 ->
<-1 3->
- Press -> button.
NOTE: The fuel consumption display can only be adapted via direct input.
Indicated on display:
Channel 3 Adaptation 100
Enter adaptation value XXXXX
- Enter required adaptation value via button pad on scan tool, filling in the initial spaces with "O."
Example:
- Required value: 90%
- Entry via button pad: 00090
Indicated on display (example only):
Channel 3 Adaptation 100 Q
Enter adaptation value 00090
- Press -Q- button to confirm input
Indicated on display:
Channel 3 Adaptation 90 Q
Store changed value?
- Press -Q- button to confirm input
Indicated on display:
Channel 3 Adaptation 90 ->
Changed value is stored
- Press -> button to terminate adaptation of fuel consumption display.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- and confirm input with Q button.
NOTE: If an incorrect entry is made the testing unit will switch to function mode.
Indicated on display:
Function is unknown or ->
cannot be carried out at the moment
- Press" button.
- Select adaptation function (function 10) and adaptation channel 03 again.
- Repeat adaptation of fuel consumption display and confirm entry with -Q- button.