Misfiring Recognition, Checking
Misfire Recognition, Checking
Special tools and equipment
- VAS 5051 or VAG 1551
Test sequence
- Connect VAS5051 tester or VAG1551 scan tool and select the control module for engine electronics using "address word" 01. Connecting VAS 5051/VAG1551 Scan Tool
Engine must run at idle for this.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block"function 08 and press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block Q
Input display group number XXX
- Press buttons -0-, -1- and -4- to select "display group number 014" and press -Q- button to confirm input.
Indicated on display:
Read measuring value block 14 ->
1 2 3 4
- Check misfire recognition.
Display Group 014:
If specified value is obtained:
- Press -> button.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
Evaluation display group 003
The following measuring value blocks indicate combustion misfires of individual cylinders:
Display Group 015:
Display Group 016:
Evaluation of measuring value blocks 15 and 16