Fuel Distance/Mileage Module: Service and Repair
Adaptation (Scan Tool Function 10)
Individual functions are called up by entering the appropriate adaptation channel numbers (listed in the adaptation table).
NOTE:
- Using measuring value blocks 10, 11, 12 and 15, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42, 43, and 44 (See measuring value blocks 013 and 014) must be adapted according to the oil quality (measuring value block 15).
- Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system..
- Measuring value blocks 125 and 126 indicate the components that are part of the powertrain data-BUS.
- Measuring value block 130 indicates the components that are part of the comfort system data-BUS.
- Measuring value block 140 indicates the components that are part of the information data-BUS.
Adaptation table :
Adaptation channel Adaptation function
02 Resetting SRI after service
03 Adaptation of fuel gauge
04 Language version of driver information display
09 Odometer
18 Adaptation of auxiliary heater
30 Adaptation of fuel gauge sender resistance range
35 Adaptation of engine speed threshold
40 Adaptation for distance driven since service
41 Adaptation for time since service
42 Adaptation for minimum mileage performance
43 Adaptation for maximum mileage performance
44 Adaptation for maximum time interval
45 Adaptation for oil quality
46 Adaptation for total consumption quantity (only gasoline engines)
60 Adaptation powertrain data-BUS
61 Adaptation comfort system data-BUS
62 Adaptation information data-BUS
Initiating "Adaptation" function 10
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0-. This selects "Adaptation", function 10.
- Press -Q- button to confirm input.
Indicated on display
Rapid data transfer Q
10-Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Enter desired adaptation channel (adaptation table).
- Press -Q- button to confirm input.
NOTE: After changing an adaptation value or ending an adaptation channel, "Adaptation " function 10 must be performed again before selecting another adaptation channel.
Adaptation of fuel consumption display
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Input Channel number XX
- Press buttons -0- and -3-.
- Press -Q- button to confirm input.
NOTE:
- Adaptation only for vehicles with on board computer.
- Value entered must be between 85% and 115%.
- Value must be entered in steps of 5%.
- If the value "100" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.
Indicated on display:
Channel 3 Adaptation 100 ->
Consumption display < -1 3- >
- Press -> button.
NOTE: Correction of fuel consumption display is only possible via direct input.
Indicated on display:
Channel 3 Adaptation 100
Input adaptation value XXXXX
- Input desired correction value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: 90%
Keypad input: 00090
Indicated on display:
Channel 3 Adaptation 100 Q
Input adaptation value 00090
- Press -Q- button to confirm input.
Indicated on display:
Channel 3 Adaptation 90 Q
Consumption display < -13- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 3 Adaptation 90 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 3 Adaptation 90 ->
Changed value is stored
- Conclude adaptation of the fuel consumption display by pressing the -> button.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10-Adaptation
- Press -Q- button to confirm input.
NOTE: If input is incorrect, tester switches to function mode.
Indicated on display:
Function is unknown Or ->
cannot be carried out at the moment
- Press -> button.
- Select "Adaptation" function 10 again and select adaptation channel 03.
- Perform correction of fuel gauge again.