Operation CHARM: Car repair manuals for everyone.

Adaptation Channel 61 - Adaptation For Comfort System Can-Bus




Adaptation (function 10)
individual functions are called up by entering the appropriate adaptation channel numbers (see adaptation table).


NOTE:
- Using measuring value blocks 010, 011, 012 and 015, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42, 43, 44 and 45 (Measuring value blocks 013 ) must be adapted when the instrument cluster is replaced.
- Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system..
- Measuring value blocks 125 and 126 indicate the participants in the powertrain CAN-bus.
- Measuring value block 130 indicates the participants in the comfort system CAN-bus.
- Measuring value block 140 indicates the participants in the information CAN-bus

Adaptation table

Adaptation channel Adaptation function
02 Resetting SRI after service
03 Adaptation of consumption display
04 Language versions of driver information system
09 Odometer
18 Adaptation of auxiliary heater
30 Adaptation of fuel gauge sender
35 Adaptation of engine speed threshold
40 Adaptation For distance driven since service
41 Adaptation For time since service
42 Adaptation For minimum mileage performance
43 Adaptation For maximum mileage performance
44 Adaptation For maximum time interval
45 Adaptation For oil quality
60 Adaptation powertrain CAN-bus
61 Adaptation comfort system CAN-bus
62 Adaptation information CAN-bus


Initiating "Adaptation" function 10
- Initiate output Diagnostic Test Mode of instrument cluster.


Display on VAS5051:







- In selection -1-, select the diagnostic function "10 - Adaptation".


Display on VAS5051







1 - Enter channel number Max. input value = 99
- Enter desired adaptation channel in button field -2- See Adaptation table.
- Press -Q- button to confirm input.


NOTE: After changing an adaptation value or ending an adaptation channel, "10 - Adaptation" function must be selected again before selecting another adaptation channel!


Display on VAS5051:







1 - Channel X read and test
2 - Text display of selected channel or No indication
5 - The sliding bar is positioned on the current adaptation value

A - Changing adaptation value using sliding bar:


Display on VAS5051:







- Move sliding bar -5- into desired direction or press on the surface beside the sliding bar, to move it in the desired direction.
- Press "Save" button -4-.


NOTE: If the "Save" button is not indicated on display, only a direct input via the keypad is possible.


Display on VAS5051:







1 - Channel X save
2 - Text display of selected channel or No indication
4 - original value X new value X
- Confirm new adaptation value by pressing the "take over" button -3-.


Display on VAS5051:







1 - Channel X Value X stored
- End function "10 - Adaptation" by pressing <- button.

B - Change adaptation value via direct input:


Display on VAS5051:







- Press "Keypad" button -3-.


Display on VAS5051:







1 - Enter adaptation value input value 0 to 65535
- Enter 5-digit adaptation value in button field -2-. If necessary, insert zeros in front.

Example:
Desired input value: 1
Keypad input: 00001
- Press -Q- button to confirm input.


Display on VAS5051:







1 - Channel X save
2 - Text display of selected channel or No indication
4 - original value X new value X
- Confirm new adaptation value by pressing the "take over" button -3-.


Display on VAS5051:







1 - Channel X Value X stored
- End function "10 - Adaptation" by pressing <- button.

Adaptation channel 61 -Adaptation For comfort system CAN-bus


Display on VAS5051:







- Select function "61" in button field -2- For "Adaptation channel 61" and press Q button to confirm input.


Display on VAS5051:







1 - Channel 61 read and test
2 - No indication
3 - Keypad - only direct input via the keypad is possible
4 - The sliding bar is positioned on the current adaptation value


NOTE:
- The adaptation values of the table will be entered.
- When replacing instrument cluster, observe.


Installed control modules (addition of corresponding adaptation values) that participate in the A6 Comfort system CAN-bus are added (See measuring value block).


NOTE: The instrument cluster, which supports CAN, is not indicated in the measuring value block, but must be added anyway.


Equipment Adaptation value
Instrument cluster 256
Tire pressure 512

Example: Tire pressure control
- instrument cluster + tire pressure = 256 + 512=768

- Change adaptation value via direct input = "B - Change adaptation value via direct input".
- Enter 5-digit adaptation value. Insert zeros in front.

Example:
Desired input value: 768 with tire pressure control
Keypad input: 00768


Display on VAS5051 after performed adaptation:







1 - Channel 61 Value 768 stored