Part 2
Adaptation of the engine speed threshold
This function is used to adapt the offset value for the engine speed threshold to the dynamic oil pressure warning.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Insert channel number XX
- Press buttons -3- and -5-.
- Press -Q- button to confirm input.
Indicated on display: Adaptation value is displayed, for example 0.
Channel 35 Adaptation 0 ->
< - 1 3- >
NOTE:
- The adaptation value of 0 corresponds to the value set at the factory for the oil pressure warning if the oil pressure drops below 1.2 bar at 1500 rpm.
- The adaptation can be performed in four steps (0-1000).
- The adaptation value of "250" changes the engine speed threshold to 1750 rpm.
- If the value "0" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.
- Press -> button.
Indicated on display
Channel 35 Adaptation 0
Input adaptation value XXXXX
- Input adaptation value using keypad, filling initial positions with "0", for example, 00250.
Indicated on display
Channel 35 Adaptation 0 Q
Input adaptation value 00250
- Press -Q- button to confirm input.
Indicated on display
Channel 35 Adaptation 250 Q
< - 1 3- >
- Press -Q- button to confirm input.
Indicated on display
Channel 35 Adaptation 250 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 35 Adaptation 250 ->
Changed value is stored
- End adaptation of the engine speed threshold by pressing the button.
Distance driven since service
This function is used to input the distance in miles since the last service.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Input channel number XX
- Press buttons -4- and -0-.
- Press -Q- button to confirm input.
Indicated on display
Channel 40 Adaptation 8 ->
Actual value Insp. in 100 Miles < - 1 3- >
Indicated on display: The display indicates the number of miles driven since the last service (here for example, 8 indicates 800 miles)
NOTE:
- Input of current specified value is only possible in units of 100 miles, therefore indication in display also changes in 100 mile units.
- Observe notes when replacing instrument cluster. Read Measuring Value Block (Scan Tool Function 08)
- Values can only be input directly using the scan tool keypad.
- In countries where speedometers are calibrated in miles, adaptation can be performed in miles.
- If an incorrect value is input, the "Adaptation" function is terminated and must be reinitiated.
- Press -> button.
Indicated on display
Channel 5 Adaptation
Input adaptation value XXXXX
- Input desired value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: for example, 1000 miles
Keypad input: 00010
Indicated on display
Channel 40 Adaptation 8 Q
Input adaptation value 00010
- Press -Q- button to confirm input.
Indicated on display
Channel 40 Adaptation 10 Q
Actual value Insp. in 100 Miles < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display
Channel 40 Adaptation 10 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 40 Adaptation 10 ->
Changed value is stored
- End adaptation of distance driven since service by pressing the -> button.
Time since service
This function is used to input the time in days since the last service.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Input channel number XX
- Press buttons -4- and -1-.
- Press -Q- button to confirm input.
Indicated on display
Login procedure Q
Enter code number 13861
- Press -Q- button to confirm input.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- to select "Adaptation" function 10.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display: Time in days since last service is displayed (here for example 110 represents 110 days)
Channel 41 Adaptation 110 ->
Actual value Insp. in 1 days < - 1 3- >
NOTE:
- Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
- Observe notes when replacing instrument cluster. Read Measuring Value Block (Scan Tool Function 08)
- Values can only be input directly using the scan tool keypad.
- If an incorrect value is input, the "Adaptation" function is terminated and must be reinitiated.
- Press -> button.
Indicated on display:
Channel 41 Adaptation 110
Input adaptation value XXXXX
- Input desired value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: for example 200 days
Keypad input: 00200
Indicated on display
Channel 9 Adaptation 2 Q
Input adaptation value 08963
- Press -Q- button to confirm input.
Indicated on display
Channel 41 Adaptation 110 Q
Input adaptation value 00200
- Press -Q- button to confirm input.
Indicated on display
Channel 41 Adaptation 200 Q
Actual value Insp. in 1 days < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display
Channel 41 Adaptation 200 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 41 Adaptation 200 ->
Changed value is stored
- End adaptation of time since service by pressing the -> button.
Minimum mileage
With this function, a minimal mile performance for the service display will be specified.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Insert channel number XX
- Press buttons -4- and -2-.
- Press -Q- button to confirm input.
Indicated on display: The minimum mileage performance up to a service will be displayed (here for example 8 represents 8000 miles).
Channel 42 Adaptation 8 ->
min-value oil in 1000 Miles < - 1 3- >
NOTE:
- The adaptation value entered for the relevant engine variant must match the value in the table.
- The currently valid specifications can be found in the "Maintenance" book.
- Input of current specified value is only possible in units of 1000, therefore indication in display also changes in 1000 units.
- In countries where speedometers are calibrated in miles, adaptation can be performed in miles.
- Values can only be input directly using the scan tool keypad.
- If an incorrect value is input, the "Adaptation" function is terminated and must be reinitiated.
- Press -> button.
Indicated on display
Channel 42 Adaptation 8
Input adaptation value XXXXX
- Input specified value using keypad, filling initial positions with "0".
Specification: 8000 Miles i.e. 5000 Miles (1.8l Turbo)
Keypad input: 00008
Indicated on display
Channel 42 Adaptation 8 Q
Input adaptation value 00008
- Press -Q- button to confirm input.
Indicated on display
Channel 42 Adaptation 8 Q
min-value oil in 1000 Miles < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display
Channel 42 Adaptation 8 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display
Channel 42 Adaptation 8 ->
Changed value is stored
- End adaptation of the minimum mileage by pressing the -> button.
Maximum mileage
This function is used to specify a fixed maximum mileage performance in the instrument cluster for the SRI.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display
Adaptation
Input channel number XX
- Press buttons -4- and -3-.
- Press -Q- button to confirm input.
Indicated on display: The maximum mileage performance up to a service will be displayed (here for example 8 represents 8000 miles).
Channel 43 Adaptation 8 ->
max-value oil in 1000 Miles < - 1 3- >
NOTE:
- The adaptation value entered for the relevant engine variant must match the value in the table.
- The currently valid specifications can be found in the "Maintenance" book.
- Input of current specified value is only possible in units of 1000, therefore indication in display also changes in 1000 units.
- In countries where speedometers are calibrated in miles, adaptation can be performed in miles.
- Values can only be input directly using the scan tool keypad.
- If an incorrect value is input, the "Adaptation" function is terminated and must be reinitiated.
- Press -> button.
Indicated on display:
Channel 43 Adaptation 8
Input adaptation value XXXXX
- Input specified value using keypad, filling initial positions with "0".
Input value: e.g. 8000 Miles i.e. 5000 Miles (1.8l Turbo)
Keypad input: 00008
Indicated on display:
Channel 43 Adaptation 8 Q
Input adaptation value 00008
- Press -Q- button to confirm input.
Indicated on display:
Channel 43 Adaptation 8 Q
max-value oil in 1000 Miles < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 43 Adaptation 8 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 43 Adaptation 8 ->
Changed value is stored
- Conclude adaptation of maximum mileage by pressing the -> button.
Maximum time interval
This function is used to set a fixed maximum time in days in the instrument cluster for the SRI.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Press buttons -4- and 4-.
- Press -Q- button to confirm input.
Indicated on display: The display indicates the maximum time interval in days to the next service (for example, 365 represents 365 days).
Channel 44 Adaptation 365 ->
max-value Insp. in 1 days < - 1 3- >
NOTE:
- The adaptation value entered for the relevant engine variant must match the value in the table.
- The currently valid specifications can be found in the "Maintenance" book.
- Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
- Values can only be input directly using the scan tool keypad.
- If an incorrect value is input, the "Adaptation" function is terminated and must be reinitiated.
- Press -> button.
Indicated on display:
Channel 44 Adaptation 365
Input adaptation value XXXXX
- Input specified value using keypad, filling initial positions with "0".
Input value: for example 365 days
Keypad input: 00365
Indicated on display:
Channel 44 Adaptation 365 Q
Input adaptation value 00365
- Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 Q
max-value Insp. in 1 days < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 44 Adaptation 365 ->
Changed value is stored
- End adaptation of maximum time interval by pressing the button.
Adaptation of oil quality
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Press buttons -4- and 5-.
- Press -Q- button to confirm input.
NOTE:
- The oil quality must be adapted after every service.
- The adaptation value can be adjusted from 1 - 4. Every value between 1-4 has a corresponding maximum mileage (channel 43) and a maximum time (channel 44). For US vehicles the number "1" must be entered, this will ensure that the maximum mileage performance is 8000 miles (Marelli instrument cluster) or 8100 miles (VDO instrument cluster) and the maximum time is 365 days.
- The adaptation value entered for the relevant engine variant must match the value in the table.
- The currently valid specifications can be found in the "Maintenance" book.
Indicated on display:
Channel 45 Adaptation 2 ->
oil quality < - 1 3- >
- Press -> button.
Indicated on display:
Channel 45 Adaptation 2
Input adaptation value XXXXX
- Input specified value using keypad, filling initial positions with "0".
Input value: for example 1
Keypad input: 00001
Indicated on display:
Channel 45 Adaptation 1 Q
Input adaptation value 00001
- Press -Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 1 Q
oil quality < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 1 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 1 ->
Changed value is stored
- Conclude adaptation of oil quality by pressing the -> button.
Adaptation of total consumption quantity
NOTE: This adaptation channel is only used for gasoline powered vehicles.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Press buttons -4- and -6-.
- Press -Q- button to confirm input.
NOTE:
- Displayed value must be transferred when replacing instrument cluster.
-The value indicated in liters does not represent actual consumption, but rather a value for the Service Reminder Indicator (SRI) calculated from various engine data and mileage performance.
Indicated on display:
Channel 46 Adaptation 300 ->
Consumption amount in 1 Liter < - 1 3- >
- Press -> button.
Indicated on display:
Channel 46 Adaptation 300
Input adaptation value XXXXX
- Input displayed value via scan tool keypad, while filling initial positions with "0".
Desired input value: 300 liters
Keypad input: 00300
Indicated on display:
Channel 46 Adaptation 300 Q
Input adaptation value 00300
- Press -Q- button to confirm input.
Indicated on display:
Channel 46 Adaptation 300 Q
Consumption amount in 1 Liter < - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 46 Adaptation 300 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 46 Adaptation 300
Changed value is stored
- Conclude adaptation of total consumption quantity by pressing the -> button.
Adaptation for powertrain data-BUS
NOTE:
- The adaptation values of the table are input.
- Observe notes when replacing instrument cluster. Read Measuring Value Block (Scan Tool Function 08)
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number
- Press buttons 6- and -0-.
- Press -Q- button to confirm input.
Indicated on display:
Channel 60 Adaptation 1035 ->
< - 1 3- >
- Press -> button.
Indicated on display:
Channel 60 Adaptation 1035
Input adaptation value XXXXX
- Input desired value using table on using scan tool keypad, filling initial positions with "0" if necessary.
for example desired input value: 1033 for manual transmission
Keypad input: 01033
Indicated on display:
Channel 60 Adaptation 1035 Q
Input adaptation value 01033
- Press -Q- button to confirm input.
Indicated on display:
Channel 60 Adaptation 1033 Q
< - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 60 Adaptation 1033 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 60 Adaptation 1033 ->
Changed value is stored
- Conclude adaptation of powertrain data-BUS by pressing the button.
Table:
Equipment Adaptation value
Engine 1
Transmission 2
Brake 4
A/C 8
ADR 32
Instrument cluster 1024
Installed control modules (addition of corresponding adaptation values) that participate in the A4/S4 powertrain data BUS (measuring value block) are added. Read Measuring Value Block (Scan Tool Function 08)
NOTE: The instrument cluster, which supports CAN, is not indicated in the measuring value block, but must be added anyway.
Example: Manual transmission
- Engine + A/C + instrument cluster = 1 + 8 + 1024 = 1033
Example: Automatic transmission
- Engine + transmission + A/C + instrument cluster = 1 + 2 + 8 + 1024 = 1035
Adaptation for comfort system data-BUS
NOTE:
- The adaptation values of the table are input.
- Observe notes when replacing instrument cluster. Read Measuring Value Block (Scan Tool Function 08)
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Press buttons -6- and -1-.
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 0 ->
< - 1 3- >
- Press -> button.
Indicated on display:
Channel 61 Adaptation 0
Input adaptation value XXXXX
- Using table input desired value using scan tool keypad, filling initial positions with "0".
for example desired input value: 768 with tire pressure control
Keypad input: 00768
Indicated on display:
Channel 61 Adaptation 0 Q
Input adaptation value 00768
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 Q
< - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 61 Adaptation 768 ->
Changed value is stored
- Conclude adaptation of comfort system data-BUS by pressing the button.
Table:
Equipment Adaptation value
Instrument cluster 256
Tire pressure 512
Parking assistance 16384
Auxiliary heater 32768
Installed control modules (addition of corresponding adaptation values) that participate in the A4/S4 Comfort system data-BUS Read Measuring Value Block (Scan Tool Function 08)
NOTE: The instrument cluster, which supports CAN, is not indicated in the measuring value block, but must be added anyway.
Example: Tire pressure control
- Instrument cluster + tire pressure = 256 + 512 = 768
Adaptation for information data-BUS7
NOTE:
- The adaptation values of the table are input.
- Observe notes when replacing instrument cluster. Read Measuring Value Block (Scan Tool Function 08)
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Input channel number XX
- Press buttons -6- and -2-.
- Press -Q- button to confirm input.
Indicated on display:
Channel 62 Adaptation 0 ->
< - 1 3- >
- Press -> button.
Indicated on display:
Channel 62 Adaptation 0
Input adaptation value XXXXX
- Using table input desired value using scan tool keypad, filling initial positions with "0".
for example desired input value: 4 with Navigation system
Keypad input: 00004
Indicated on display:
Channel 62 Adaptation 0 Q
Input adaptation value 00004
- Press -Q- button to confirm input.
Indicated on display:
Channel 62 Adaptation 4 Q
< - 1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 62 Adaptation 4 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 62 Adaptation 4 ->
Changed value is stored
- Conclude adaptation of information data-BUS by pressing the button.
Table:
Equipment Adaptation value
without Navigation 0
with Navigation 4
Installed control modules (addition of corresponding adaptation values) that participate in the A4/S4 information data BUS are added. Read Measuring Value Block (Scan Tool Function 08)
Example: with Navigation system
- Navigation system = 4