Operation CHARM: Car repair manuals for everyone.

Read Measuring Value Block (Scan Tool Function 08) For Transmissions With Hydraulic Control -E18/2-



Read Measuring Value Block (scan tool function 08) for transmissions with hydraulic control -E18/2- - 5 Spd. Automatic Transmission 01V

Note:
For transmissions with hydraulic control -E17-, "Read Measuring Value Block"

CAUTION:
To avoid risk of accidents during measuring and test drives, note safety precautions


Procedure

- Connect VAS 5051 tester or V.A.G 1551 scan tool and select Transmission Control Module (TCM) using "address word" 02.

Ignition must remain switched on for this procedure.

Rapid data transfer HELP
Select function XX

Indicated on display

- Press PRINT button to turn on Scan Tool (ST) printer. Indicator lamp in button must light up.
- Press buttons -0- and -8- to select "Read Measuring Value Block" and press -Q- button to confirm input.

Read measuring value block Q
Input display group number XXX

When indicated on display:

- Enter desired display group number.
- Confirm input using the -Q- button.

Read measuring value block 1 ->
1 2 3 4

Indicated on display (example) for display group 001:

Note:
^ Explanation of values in individual display fields test table.
^ Display can be printed out when printer is switched on.
^ To switch to a different display group, proceed as follows:





- If specified values are obtained in all display fields, press -> button.

Rapid data transfer HELP
Select function XX

Indicated on display (function selection):

Overview of selectable display group numbers for transmission with hydraulic control -E18/2-

Display Group Number 001-004:




Display Group Number 005-008:




Display Group Number 009-125:





Note:
^ When the printer is switched on, the contents of the display will be printed out.
^ If specified values are not obtained in all display fields:

- Press -> button.

Rapid data transfer HELP
Select function XX

Indicated on display