Reading
Read Measuring Value Block (Function 08)
The current central locking system status can be ascertained using the "Read Measuring Value Block" function.
- Starting central locking system On Board Diagnostic (OBD). Initial Inspection and Diagnostic Overview
Indicated on display:
Rapid data transfer HELP
Select function XX
- Enter "08" to select the function "Read Measuring Value Block" and confirm entry with Q key.
Indicated on display:
Read Measuring Value Block Q
Enter display group number XXX
- Enter desired display group and confirm input with Q key.
Display for display group 001 (example):
Read Measuring Value Block 1 ->
1 2 3 4
- If specified values are attained in all display fields, press key.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX