Operation CHARM: Car repair manuals for everyone.

Odometer, Adaptation




Odometer, Adaptation

This function is used to set the correct odometer reading after replacing the instrument cluster.

Preparation

NOTE:
- The adaptation function can only be performed on instrument clusters with a maximum of 100 kilometers or 63 miles indicated on counter.
- The adaptation procedure can only be performed once on any one instrument cluster.
- The adaptation value entered must be higher than the existing value (over 100 kilometers or 63 miles).
- If an incorrect value is entered and confirmed, it cannot be changed. In this case the instrument cluster must be replaced.
- Record instrument cluster input values and proceed with initial adaptations (code instrument cluster, etc.)

Adaptation

Indicated on display:

Rapid data transfer HELP
Select function XX


- Press buttons -1 - and -1 - to select "Login procedure" function 11

Indicated on display:

Rapid data transfer Q
11 - Login procedure


- Press -Q- button to confirm input

Indicated on display:

Login procedure
Enter code number XXXXX


- Enter code number 13861.

Indicated on display:

Login procedure
Enter code number 13861


- Press -Q- button to confirm input

Indicated on display:

Rapid data transfer HELP
Select function XX


- Press buttons -1- and -0- to select "Adaptation" function 10.

Indicated on display:

Rapid data transfer Q
10 -Adaptation


- Press -Q- button to confirm input

Indicated on display:

Adaptation
Enter channel number XX


- Press buttons -0- and -9- to access "channel 09".
- Press -Q- button to confirm input

Indicated on display:

Channel 9 Adaptation 0 ->
<-1 3->


NOTE: The number can only be entered directly via VAG 1551 scan tool button pad.

- Press -> button to advance the program sequence.

Indicated on display:

Channel 9 Adaptation 0 Q
Enter adaptation value XXXXX


CAUTION:
- Replacement instrument clusters calibrated in miles require input of odometer reading in miles during adaptation (DO NOT convert to kilometers).
- Replacement instrument clusters calibrated in kilometers require input of odometer reading in kilometers during adaptation.
- If an incorrect odometer display value is entered and confirmed during adaptation, it cannot be changed. In this case the instrument cluster must be replaced.


- Enter adaptation value (odometer reading) via button pad.

Example: 89627

08963







Indicated on display (example only):

Channel 9 Adaptation 0 Q
Enter adaptation value 08963


- Press -Q- button to confirm input

Indicated on display:

Channel 9 Adaptation 8963 Q
<-1 3->


- Press -Q- button to confirm input

Indicated on display:

Channel 9 Adaptation 8963 Q
Store changed value?


- Press -Q- button to confirm input

Indicated on display:

Channel 9 Adaptation 8963 ->
Changed value is stored


- Press -> to terminate adaptation of odometer.