SID: Minimum Distance, Adaptation
SID: Minimum Distance, Adaptation
This function stipulates a minimum distance for the SID.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- and confirm input with -Q- button.
Indicated on display:
Rapid data transfer Q
10 -Adaptation
- Press-Q- button to confirm input.
Indicated on display:
Adaptation
Enter channel no. XX
- Press buttons -4- and -2- to access "channel 42".
- Press-Q- button to confirm input.
Indicated on display: Display shows minimum distance until next service (here, e.g. 15 = 15000 km).
Channel 42 Adaptation 15
min-value, oil in 1000 km < -1 3- >
NOTE:
- Confirm maintenance intervals applicable to vehicle.
- Distance must be entered in steps of 1000 km. Accordingly, readout on the display will also be in steps of 1000 km.
- When using the button pad on the scan tool, the number must be entered directly.
- If an incorrect value is entered adaptation function will be terminated and must be restarted.
CAUTION:
- Replacement instrument clusters calibrated in miles require input of distance reading in miles during adaptation (DO NOT convert to kilometers).
- Replacement instrument clusters calibrated in kilometers require input of distance reading in kilometers during adaptation.
- Press -> button.
Indicated on display:
Channel 42 Adaptation 15
Enter adaptation value XXXXX
- Enter required value via scan tool button pad, filling in initial spaces with "0"
Specification: 15000 km
Entry via keypad: 00015
Indicated on display (example only):
Channel 42 Adaptation 15 Q
Enter adaptation value 00015
- Press-Q- button to confirm input.
Indicated on display:
Channel 42 Adaptation 15 Q
min-value, oil in 1000 km < -1 3- >
- Press-Q- button to confirm input.
Indicated on display:
Channel 42 Adaptation 15 Q
Store changed value?
- Press-Q- button to confirm input.
Indicated on display:
Channel 42 Adaptation 15 ->
Changed value is stored
- Press -> button to terminate adaptation of minimum distance.