Malfunction Indicator Lamp (MIL) In Instrument Cluster, Check
Check Malfunction Indicator Lamp (MIL) In Instrument Cluster
Recommended special tools and equipment
- VAG1526 multimeter or VAG1715 multimeter
- VAG1594 connector test kit
- Wiring diagram
Test requirement
- The respective fuses of Malfunction Indicator Lamp (MIL) -K83-must be OK:
Test sequence
- Switch on ignition:
exhaust MIL must light up.
If exhaust MIL does not light up when ignition is switched on:
- Switch ignition off.
- Check wire from ECM to exhaust MIL as follows.
- Connect test box to control module wiring harness, connect test box for wiring test. Test Box, Connecting For Wiring Test
- Bridge sockets 2+47 of test box with the respective adapter cables.
- Switch on ignition:
exhaust MIL must light up.
If Malfunction Indicator Lamp (MIL) does not light up:
- Switch ignition off.
- Remove instrument cluster.
- Check wire connection from Engine Control Module (ECM) to Malfunction Indicator Lamp (MIL) -K83- according to wiring diagram.
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. Diagnostic Mode 4: Reset/Erase Diagnostic Data
- Generate readiness code. Readiness Code, Generating
If no malfunctions are detected in wire from Engine Control Module (ECM) to Malfunction Indicator Lamp (MIL):
- Replace Motronic Engine Control Module (ECM) -J220-.
If exhaust MIL lights up when ignition is switched on:
- Start engine and let run at idle:
Exhaust MIL must
go out after a few seconds.
If Malfunction Indicator Lamp (MIL) does not go out:
- Switch ignition off.
- Remove instrument cluster.
- Connect test box to control module wiring harness, connect test box for wiring test. Test Box, Connecting For Wiring Test
- Check wire connection between test box socket 47 and instrument cluster for short circuit to Ground (GND) according to wiring diagram.
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. Diagnostic Mode 4: Reset/Erase Diagnostic Data
- Generate readiness code. Readiness Code, Generating
If no malfunctions are detected in wire from Engine Control Module (ECM) to Malfunction Indicator Lamp (MIL):
- Replace Motronic Engine Control Module (ECM) -J220-.