With Generic Scan Tool
Fuel Delivery, Checking
Special tools and equipment
- VAG1348/3A remote control with VAG1348/3-2 adapter cable
- Measuring container
Test requirements:
- Battery voltage at least 12 V
- Fuel filter OK
- Ignition switched off.
Test sequence
- Open cover of fuse box at left side of instrument cluster.
- Remove Fuse in fuse holder -S228- (position 28) (left row, 5th large fuse from top).
- Connect V.A.G 1348/3A remote control connection using adapter cables from VAG1348/3-2 at right terminal of socket from Fuse in fuse holder -S228- (arrow).
- Connect alligator clip to vehicle battery B+.
- Remove fuel filler cap from fuel filler tube.
- Remove engine cover -A- (arrows).
CAUTION: Fuel system is under pressure! Before opening system, place rags around the connection point. Then release pressure by carefully loosening connection.
- Disconnect fuel return hose from line connection on fuel rail pipe.
- Connect assisting hose -arrow- on distributor pipe and hold in a measuring container.
- Operate remote control for 15 seconds (keep button pressed).
- Compare fuel quantity pumped with specified value.
*) Minimum delivery rate cubic cm/15 s
**) Voltage at fuel pump with engine off and pump running (approx. 2 volts less than battery voltage).
- Install fuel return line with a new hose clamp.