Intake Manifold Change-Over Valve - N156-, Checking
Intake Manifold Change-Over Valve -N156-, Checking
Checking Intake manifold change-over valve electrically
- Disconnect connector from Intake Manifold Change-Over Valve -N156-.
- Perform a resistance measurement between the valve terminals using V.A.G 1526.
Specified value: 25 to 35 Ohms
If specified value is not obtained.
- Replace Intake Manifold Change-Over Valve -N156-.
If specified value is obtained.
- Check voltage supply.
Checking voltage supply of Intake Manifold Change-Over Valve
- Connect V.A.G 1527 voltage test lamp between connector terminal 2 and engine Ground (GND) using adapter cables from V.A.G 1594 connector test kit.
- Switch ignition on.
LED must light up.
- LED does not light up.
- Check fuse for intake manifold change-over valve (relay- and fuse holder in instrument panel, right side).
If fuse is OK.
- Check wire connection from terminal 2 of connector for intake manifold change-over valve via fuse to Motronic Engine Control Module (ECM) Power Supply Relay -J271- (relay carrier in E-box in plenum chamber) for open circuit/short circuit.
If voltage supply is OK, check wire connection.
Checking wire connection from Intake Manifold Change-Over Valve
- Connect V.A.G 1598/31 test box to wiring harness of Engine Control Module (ECM).
- Check the following wire connection for open circuit/short circuit:
Connector at wiring V.A.G 1598/31 test box or
harness, terminal Engine Control Module (ECM)
1 121
- Repair open circuit in wiring or short circuit if necessary.
- If wire connection is OK, replace Engine Control Module (ECM) and generate readiness code again.
- Check intake manifold once again for function.