O-Ring Seals For Refrigerant Circuit
O-ring Seals For Refrigerant Circuit
- Always replace, only to be used once.
- Moisten slightly with refrigerant oil before installing.
- Ensure correct positioning on line/in groove.
- Ensure cleanliness when working.
NOTE:
- Only O-rings which are resistant to refrigerant R134a and the corresponding refrigerant oil may be installed. Such O-rings are color coded to prevent mix-ups (currently "red", "light purple" or "dark purple").
- In addition to the colored O-rings, black O-rings are also used at the factory for certain connections.
- Dimensions -a- and -b- differ depending on installation of O-ring.
- In January 2003, the connections between the refrigerant lines and the various components (condenser, evaporator etc.) were converted from radial/axial sealing to radial sealing. It is only permissible to combine components with the same type of seal and the corresponding O-rings (different versions). Reliable sealing of the joints cannot be ensured if components with different forms of sealing are installed.