Components (Except Compressor, Reservoir or Receiver) Leaking or Damaged
Components (except Compressor, Reservoir Or Receiver) Leaking Or Damaged
Refrigerant Circuit Completely Empty
NOTE:
- In the event of only a mi nor leak with slow escape of refrigerant (e.g. at a small leakage point), the amount of refrigerant oil lost and the amount of moisture penetrating is not sufficient to influence operation of the air conditioner.
- The operations marked * are only to be implemented in the case of a major leak (e.g. following an accident).
- Remove malfunctioning component.
- Remove compressor.*
- Remove oil drain plug from compressor.*
NOTE:
- The oil drain plug of "Denso" and "Nippondenso" compressors is equipped with an oil seal instead of an O-ring and this is always to be replaced.
- To accelerate drainage of refrigerant oil, rotate compressor by way of clutch plate of A/C clutch for exam pie.
- Pour old refrigerant oil out of compressor* (disposal Audi-ServiceNet, Handbooks, HSO Environment 2).
- Then fill compressor with quantity of fresh refrigerant oil corresponding to quantity of refrigerant oil in replacement compressor.
- Use different refrigerant oils and quantities for the various compressors.
- To ensure compressor lubrication on start-up, at least 80 cu.cm of refrigerant oil must be poured into the compressor. The remainder can be added for example to the new reservoir or receiver.
- If dirt has penetrated into the compressor with the refrigerant circuit open (e.g. after an accident), compressor is to be replaced.
- Cleaning (flushing) refrigerant circuit with compressed air or nitrogen.
- Replace receiver* or reservoir* and restrictor.
- Assemble, evacuate and re-charge refrigerant circuit.
Refrigerant Circuit Still Containing Refrigerant
- Discharge refrigerant circuit.
- Remove malfunctioning component, flush with compressed air and collect escaping refrigerant oil.
- The new component is to be filled with the amount of refrigerant oil flushed out (plus 20 cu.cm for evaporator, plus 10 cu.cm for condenser, refrigerant pipes and refrigerant hoses) as fresh refrigerant oil fill.
- Replace restrictor.
- Assemble, evacuate and charge refrigerant circuit.