Oxygen Sensor After Catalytic Converter, Bank 2
Oxygen Sensor after Catalytic Converter, Bank 2
Removing
- Disconnect electrical connector - 3 - of oxygen sensor 2, bank 2.
2 4-pin connection for oxygen sensor 1 and heater, bank 1.
3 4-pin connection for oxygen sensor 2 and heater, bank 2.
- Open all cable ties on transmission for oxygen sensor 2 electrical wiring connection.
- Remove oxygen sensor - arrow - using tool from Ring Spanner 7 piece set (3337).
Installing
Installation of oxygen sensor is in reverse order of removal. Note the following.
• Wires of oxygen sensors must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots.
Tightening Specifications