Oxygen Sensor After Catalytic Converter, Bank 1
Oxygen Sensor after Catalytic Converter, Bank 1
Removing
- Disconnect electrical connector - 2 - of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130), bank 1.
2 4-pin connection for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) Heater 1 (behind Three Way Catalytic Converter (TWC)) (Z29), bank 1.
3 4-pin connection for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) and Oxygen Sensor (O2S) Heater 2 (behind Three Way Catalytic Converter (TWC)) (Z30), bank 2.
To remove Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130), bank 1, back of transmission must be lowered to open oxygen sensor wire routing.
Lower the automatic transmission.
Remove oxygen sensor after lowering transmission.
- Open all cable ties on transmission for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical wiring connection.
- Remove oxygen sensor using tool from ring spanner set (3337).
Installing
Installation of oxygen sensor is in reverse order of removal. Note the following.
• Wires of oxygen sensors must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.
• New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.
• For a used oxygen sensor, only coat threads with hot bolt paste. This paste must not come into contact with sensor slots.
Tightening Specifications