Fuel Pump Delivery Quantity, Checking - From 11.04
Fuel Pump Delivery Quantity, Checking (Vehicles With 8-Cyl. MPI-Engine)
Special tools, testers and auxiliary items required
- Remote control V.A.G 1348/3A with adapter cable V.A.G 1348/3-2
- Fuel-resistant measuring container
Test conditions
- Battery voltage at least 12.5 V.
- Fuel filter OK
- Fuel tank at least 1/4 filled.
- Fuel pressure regulator OK, checking.
- Ignition switched off.
Test sequence
- Open fuse box cover at left side of instrument cluster.
- Pull out fuse on fuse panel S228 (left row, 5th large fuse from top).
- Connect remote control V.A.G 1348/3A with adapter cable V.A.G 1348/3-2 to right socket terminal of S228.
- Connect alligator clip to vehicle battery (+).
- Remove fuel filler cap from fuel filler tube.
- Remove rear seat bench.
- Unbolt cover for right locking flange - arrows -.
CAUTION: The fuel system is under pressure. Before opening system, place rags around the connection area. Then release pressure by carefully loosening the connection.
- Disconnect fuel return line - 1 - by pressing release buttons.
- Connect adapter V.A.G 1318/17-1 to disconnected fuel return line and hold it in a measuring container.
- Press switch on remote control for 15 seconds.
- Compare quantity of fuel delivered with minimum delivery rate in diagram (cu.cm/15s).
NOTE: Voltage at fuel pump with engine stopped and pump running is approx. 2 volts less than battery voltage.
Installation is in reverse order of removal. Note the following:
NOTE: Secure all hose connections using hose clamps appropriate for the model type.
- Install fuel return hose.