Airbag Adapter VAS 6036 , Connecting
Airbag Adapter VAS 6036, Connecting
Special tools, testers and auxiliary items required
- Airbag adapter VAS 6036
CAUTION:
- Technician must be grounded before disconnecting ignition and ground wiring, touching door striker or body.
- The Airbag Adapter VAS 6036 must stay connected to seat until seat is installed again.
1 - Seat connector power supply connector (red)
2 - Voltage supply connector for airbag adapter (red)
3 - Airbag adapter connector (yellow)
4 - Airbag connector (yellow)
- Disconnect ignition and ground wiring.
- Connect airbag connector - 4 - to airbag adapter connector - 3 -.
If present:
- Connect voltage supply connector for airbag adapter - 2 - to voltage supply connector for seat - 1 -.