Refrigerant Circuit Quick-Release Connections
Refrigerant Circuit Quick-Release Connections
- Only valves and connections resistant to R134a refrigerant and the related refrigerant oils are to be used.
- There are different connections (OD) for high and low pressure sides.
- Discharge refrigerant circuit before removing valves or valve inserts.
- Always screw on sealing caps.
Arrangement in vehicle.
Connections with Schrader Valve
A - Service connection (soldered in)
B - Schrader valve insert
C - O-ring (for valve)
D - Cap with seal
Connections with Primary Sealing Valve
CAUTION: Before unscrewing connection, connect A/C service station and extract refrigerant. Refrigerant circuit must be empty to avoid possible injury.
Connection with High-Pressure Valve
1 - Socket with external or internal thread
2 - O-ring: 10.8 mm; 1.8 mm, identification: black or colored
3 - Valve with groove for O-ring and external or internal thread M 8x1 for cap
4 - O-ring for cap: 10.8 mm; 1.8 mm, identification: black or colored
5 - Cap
Connection with Low-Pressure Valve
1 - Socket with external thread and groove for O-ring
2 - O-ring: 7.6 mm; 1.8 mm, identification: black or colored
3 - Valve internal thread for cap M 8x1
4 - O-ring for cap: 7.6 mm; 1.8 mm, identification: black or colored
5 - Cap