Electrical Test Table, Notes
Electrical test table
Notes for electrical test table
- The socket designations for the VAG1598 adapter are identical to the terminal designations for the ABS control module -J104- in the wiring diagram.
- If the measured values do not match the specifications, refer to the corrective actions on the right side of the table.
- Use the VAG1594A connector kit for continuity tests.
- If measured values differ only slightly from specified values, clean sockets and connectors of the testers and test leads (using G 000 700 04 contact spray) and repeat test. Before replacing the relevant components, check wires and connections and also repeat resistance measurement at component, especially for specified values under 10 ohms.