Operation CHARM: Car repair manuals for everyone.

After-Run Coolant Pump, Checking






After-Run Coolant Pump, Checking

Use only gold-plated terminals when servicing terminals in the electrical harness connector of After-Run Coolant Pump (V51).

Special tools, testers and auxiliary items required

Multimeter.

Wiring diagram.

Test requirements

The Coolant Circulation Pump Relay (J151) OK.

The After-Run Coolant Pump (V51) fuse OK.





Battery voltage at least 12.5 volts.

All electrical consumers such as, lights and rear window defroster, switched off.

Vehicles with automatic transmission, shift selector lever into position "P" or "N".

A/C switched off.

Ground (GND) connections between engine/transmission/chassis OK.

Ignition switched off.

Engine cold.

Test procedure

- Perform a preliminary check to verify the customers complaint. Refer to => [ General Diagnosis ] General Diagnosis.

Start diagnosis

- Disconnect the After-Run Coolant Pump (V51) electrical harness connector - 3 -.





Checking voltage

Switch the ignition on.

- Using a multimeter, check the After-Run Coolant Pump (V51) electrical connector terminal 1 to Ground (GND) for voltage.





Specified value: battery voltage.

Switch the ignition off.

If the specified value was not obtained:

- Check the wiring from the After-Run Coolant Pump (V51) electrical connector terminal 1 to the Coolant Circulation Pump Relay (J151) socket 2/87 for a short circuit to Ground (GND), or an open circuit.

- Check the electrical harness connector for damage, corrosion, lose or broken terminals.

- If necessary, repair the wiring connection.

If no malfunctions are found in the wiring:

Checking Ground (GND)

- Using a multimeter, check the After-Run Coolant Pump (V51) electrical connector terminal 2 to Ground (GND) for resistance.





Specified value: 1.5 ohms Max.

If the specification was not obtained:

- Check the wiring for a short circuit to, Battery (+), or an open.

- Check the electrical harness connector for damage, corrosion, lose or broken terminals.

- If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring:

- Replace the After-Run Coolant Pump (V51).

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Readiness Code.

- End of diagnosis.