With Generic Scan Tool
Wastegate Bypass Regulator Valve N75, Checking
Special tools, testers and auxiliary items required
- Multimeter.
- Wiring diagram.
Test requirements
- The Motronic Engine Control Module (ECM) J220 fuses OK.
- Battery voltage at least 12.5 volts.
- All electrical consumers such as, lights and rear window defroster, switched off.
- On vehicles with automatic transmission, selector lever in position "P" or "N" .
- A/C switched off.
- Ground (GND) connections between engine/transmission/chassis OK.
- Ignition switched off.
Procedure
- Remove the engine cover with air filter.
Checking internal resistance
- Disconnect the Wastegate Bypass Regulator Valve N75 electrical harness connector - 1 -.
- Using a multimeter , check the Wastegate Bypass Regulator Valve N75 terminals 1 to 2 for resistance.
Specified value: 20 to 30 Ohms (at approx. 20 degrees C)
If the specification was not obtained:
- Replace the Wastegate Bypass Regulator Valve N75.
If the specification is obtained:
Checking Voltage supply
- Using a multimeter , check the Wastegate Bypass Regulator Valve N75 electrical harness connector terminal 1 to Ground (GND).
Wastegate Bypass Regulator Valve Measure to
N75 electrical harness connector terminal
1 Engine Ground (GND)
- Operate the starter briefly.
Specified value: battery voltage.
- Switch the ignition off.
If the specification was not obtained:
- Check the wiring for a short circuit to Battery positive (+) or an open circuit.
- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
- If necessary, repair the wiring connection.
If no malfunction is found in the wiring:
If the manufacturers test box is being used. Perform the following step.
- Install the test box.
If the manufacturers test box is not being used. Perform the following step.
- Remove the Motronic Engine Control Module (ECM) J220.
- Using a multimeter , check the Wastegate Bypass Regulator Valve N75 electrical harness connector terminal 2 to the Motronic Engine Control Module (ECM) J220 electrical harness connector 104 for an open circuit.
Wastegate Bypass Regulator Valve Motronic Engine Control Module
N75 electrical harness connector (ECM) J220 electrical connector test
terminal box socket
2 104
Specified value: 1.5 Ohms max.
If the specification is not obtained:
- Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).
- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
- If necessary, repair the faulty wiring connection.
If no malfunction is detected in the wiring and if the voltage supply was OK:
- Replace the Motronic Engine Control Module (ECM) J220.
- Install the engine cover with air filter.
Final procedures
After the repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. Diagnostic Mode 03 - Read DTC Memory
2. If necessary, erase the DTC memory. Diagnostic Mode 04 - Erase DTC Memory
3. If the DTC memory was erased, generate readiness code.
- End of diagnosis.