Measured Value Block, Reading
Measured Value Block, reading - 01V, 5 Speed A/T
CAUTION! Please observe safety precautions.
Test procedure
- Connect VAS 5051 Vehicle Diagnosis, Measurement- and Information System and in selection touch vehicle system "02 - Transmission Electronics". Ignition must be switched ON.
or, depending on the desired operation:
- Start engine.
Display on VAS 5051:
- In selection touch -1- diagnostic function "08 - Read Measured Value Block".
Display on VAS 5051:
1- Enter display group
- On key pad -2- enter desired 3-digit display group number refer to List of Display Groups, and confirm entry by touching Q-button.
Example:
- Entry "001" for "Display group number 001" and confirm by touching Q button.
Display on VAS 5051:
1- Read Measured Value Block
2- Display field 1
Display field 2
Display field 3
Display field 4
3- Display Group X
Note:
^ If a display field is not being used, there will be no display.
^ To switch to another display field, proceed as follows:
- End function "08 - Read Measured Value Block" by touching < button.