Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor Before Catalytic Converter, Bank 1






Oxygen Sensor Before Catalytic Converter, Bank 1

Special tools, testers and auxiliary items required

Ring Spanner 7-Piece Set for Oxygen Sensor (3337 )

Removing

- Pull rear engine cover off - arrows -.





- Pull front engine cover off - arrows -.





- Remove bolts - arrows -.





- Remove the air duct - 1 - and - 2 -.

- Disconnect check valve - 1 - from air duct hose.





- Remove the air duct hose, thereby loosening the hose clamp - 2 - and opening the clips - arrows -.

- Remove pin from spreader clips - arrow -.





- Remove air filter housing.

- Disconnect the electrical harness connector - 1 - for heated oxygen sensor (G39) and free up wire.





Ignore - 2 -.

- Remove the oxygen sensor - 2 - with the ( 3337).





To improve clarity, the removed engine is shown.

Installing

Installation is in reverse order of removal, note the following:

New oxygen sensors are coated with assembly paste; the paste must not get into slots of oxygen sensor body.

When reinstalling the previously used oxygen sensor, coat thread with hot bolt paste. Paste must not get on to slits of sensor body.

Electrical wire of oxygen sensor must always be secured in the same position when installing so that contact with the exhaust pipe is avoided.

Tightening Specifications