Reading Measured Value Block






Reading Measured Value Block

CAUTION!
Please observe safety precautions => [ OBD Program Safety Precautions ] 01V,01VA Transmission.

=> [ Selectable Display Group Numbers ] Selectable Display Group Numbers

=> [ Test Table ] Test Table

Test Procedure

- Connect Vehicle Diagnosis, Measurement- and Information System (VAS5051) => [ VAS 5051, Connecting and Selecting Functions ] VAS 5051, Connecting and Selecting Functions and in selection touch vehicle system "02 - Transmission Electronics". Ignition must be switched ON.

or, depending on the desired operation:

- Start engine.

Display on (VAS5051):





- In selection touch - 1 - diagnostic function " 08 - Read Measured Value Block".

Display on (VAS5051):





1. Enter display group

- On key pad - 2 - enter desired 3-digit display group number List of Display Groups, => [ Selectable Display Group Numbers ] Selectable Display Group Numbers and confirm entry by touching Q-button.

Example:

- Enter "001" for "Display group number 001" and confirm by touching Q button.

Display on (VAS5051):





1. Read Measured Value Block

2. Display field 1, Display field 2, Display field 3, Display field 4

3. Display Group X

If a display field is not being used, there will be no display.

To switch to another display field, proceed as follows:





- End function "08 - Read Measured Value Block" by touching arrow button.